« Previous - Version 6/49 (diff) - Next » - Current version
Jeremy Wright, 09/20/2012 10:52 pm


Operating Manual v1.0

Unpacking After Transport

  • Check shipping container(s) for:
    • Test stand
    • Concrete block
    • Box of accessories
      • Launch controller
      • D motor spacer ring
      • Motor mount adapters (A, B, and C to D/E size)
      • Thermocouple attachment tape (high temp)
    • Computer and USB cable
    • Motors to test (with igniters and igniter plugs)
    • Fire extinguisher and maybe a bucket for water

Test Stand Setup

  • Place concrete block in location where test stand will be operated
  • Set test stand on concrete block
  • Create the safety perimeter.
    • Delineate no stand zone for both proximity and positions
      • Use length of cord for the igniter (radius of operations)
      • Exclusion zones exist behind where exhaust escapes (30 degree cone), and in front on each side of the exhaust T (30 degree cone on each side)
  • Set up the management area for test.
    • Igniter
      • Clip the igniter to a part of the test stand and deploy the cable to its full length and place it where the test(s) will be run from
    • Computer
      • Set up computer
      • Boot computer
      • Run USB cable from computer to test stand
      • Connect Arduino-based DAQ system to USB cable at test stand
      • Start the Test Stand App
      • Ensure DAQ system and Computer are both running and connected

Prepare For Test

  • Test sensors
    • Push on thrust sensor and confirm current value slider responds
    • Put fingers around thermocouple(s) (after ensuring it is not hot) and confirm plot responds