h1. Operating Manual v1.0 h2. Unpacking After Transport * Check shipping container(s) for: ** Test stand ** Concrete block ** Box of accessories *** Launch controller *** D motor spacer ring *** Motor mount adapters (A, B, and C to D/E size) *** Thermocouple attachment tape (high temp) ** Computer and USB cable ** Motors to test (with igniters and igniter plugs) ** Fire extinguisher and maybe a bucket for water h2. Test Stand Setup * Place concrete block in location where test stand will be operated * Set test stand on concrete block * Create the safety perimeter. ** Delineate no stand zone for both proximity and positions *** Use length of cord for the igniter (radius of operations) *** Exclusion zones exist behind where exhaust escapes (30 degree cone), and in front on each side of the exhaust T (30 degree cone on each side) * Set up the management area for test. ** Igniter *** Clip the igniter to a part of the test stand and deploy the cable to its full length and place it where the test(s) will be run from ** Computer *** Set up computer *** Boot computer *** Run USB cable from computer to test stand *** Connect Arduino-based DAQ system to USB cable at test stand *** Start the Test Stand App *** Ensure DAQ system and Computer are both running and connected h2. Prepare For Test * Test sensors ** Push on thrust sensor and confirm current value slider responds ** Put fingers around thermocouple(s) (after ensuring it is not hot) and confirm plot responds