Operating Manual v1 0
Version 6 (Jeremy Wright, 09/20/2012 10:52 pm)
| 1 | 1 | Jeremy Wright | h1. Operating Manual v1.0 |
|---|---|---|---|
| 2 | 1 | Jeremy Wright | |
| 3 | 1 | Jeremy Wright | h2. Unpacking After Transport |
| 4 | 3 | Jeremy Wright | |
| 5 | 5 | Jeremy Wright | * Check shipping container(s) for: |
| 6 | 2 | Jeremy Wright | ** Test stand |
| 7 | 2 | Jeremy Wright | ** Concrete block |
| 8 | 2 | Jeremy Wright | ** Box of accessories |
| 9 | 2 | Jeremy Wright | *** Launch controller |
| 10 | 4 | Jeremy Wright | *** D motor spacer ring |
| 11 | 4 | Jeremy Wright | *** Motor mount adapters (A, B, and C to D/E size) |
| 12 | 4 | Jeremy Wright | *** Thermocouple attachment tape (high temp) |
| 13 | 4 | Jeremy Wright | ** Computer and USB cable |
| 14 | 4 | Jeremy Wright | ** Motors to test (with igniters and igniter plugs) |
| 15 | 5 | Jeremy Wright | ** Fire extinguisher and maybe a bucket for water |
| 16 | 1 | Jeremy Wright | |
| 17 | 1 | Jeremy Wright | h2. Test Stand Setup |
| 18 | 5 | Jeremy Wright | |
| 19 | 5 | Jeremy Wright | * Place concrete block in location where test stand will be operated |
| 20 | 5 | Jeremy Wright | * Set test stand on concrete block |
| 21 | 5 | Jeremy Wright | * Create the safety perimeter. |
| 22 | 5 | Jeremy Wright | ** Delineate no stand zone for both proximity and positions |
| 23 | 5 | Jeremy Wright | *** Use length of cord for the igniter (radius of operations) |
| 24 | 5 | Jeremy Wright | *** Exclusion zones exist behind where exhaust escapes (30 degree cone), and in front on each side of the exhaust T (30 degree cone on each side) |
| 25 | 6 | Jeremy Wright | * Set up the management area for test. |
| 26 | 6 | Jeremy Wright | ** Igniter |
| 27 | 6 | Jeremy Wright | *** Clip the igniter to a part of the test stand and deploy the cable to its full length and place it where the test(s) will be run from |
| 28 | 6 | Jeremy Wright | ** Computer |
| 29 | 6 | Jeremy Wright | *** Set up computer |
| 30 | 6 | Jeremy Wright | *** Boot computer |
| 31 | 6 | Jeremy Wright | *** Run USB cable from computer to test stand |
| 32 | 6 | Jeremy Wright | *** Connect Arduino-based DAQ system to USB cable at test stand |
| 33 | 6 | Jeremy Wright | *** Start the Test Stand App |
| 34 | 6 | Jeremy Wright | *** Ensure DAQ system and Computer are both running and connected |
| 35 | 6 | Jeremy Wright | |
| 36 | 6 | Jeremy Wright | h2. Prepare For Test |
| 37 | 6 | Jeremy Wright | |
| 38 | 6 | Jeremy Wright | * Test sensors |
| 39 | 6 | Jeremy Wright | ** Push on thrust sensor and confirm current value slider responds |
| 40 | 6 | Jeremy Wright | ** Put fingers around thermocouple(s) (after ensuring it is not hot) and confirm plot responds |