Tone Ring Assembly
Version 9 (J. Simmons, 02/04/2018 09:12 pm) → Version 10/15 (J. Simmons, 02/04/2018 09:12 pm)
h1. Tone Ring Assembly
{{>toc}}
h2. Tools
* Holoseat Test Stand
h2. Materials
* (optional) Instant/super glue (prefer Loctite Super Glue Ultragel Control)
* (1) 18PTR-01: 18 Pole Tone Ring Base
* (1) 18PTR-02: Tone Ring Cover
* (36) 18PTR-03: N52 3/16" x 3/16" Neodymium Cylinder Magnets
h2. Safety Issues
* Use safety glasses when working with small, high powered magnets to avoid eye injury from flying magnets
h2. Product
HS-03: 18 Pole Tone Ring
h2. Procedure
h3. 1. Place Magnets
# TBD
h3. 3. Verify Magnet Placement
# Set up the Holoseat Test Stand
## Ensure the calibrated sensor is attached to the sensor controller
## Ensure the power and USB connections are all configured according to the test stand operating instructions
## Place the new tone ring onto the tone ring adapter
# Run test
## Clear the sensor stats
## Run the stepper motor 1 revolution, in a CW direction, at 30 RPM
## Get the sensor stats and verify the number of reported poles is 18
# Remove the tone ring from the tone ring adapter
h3. 4. Complete the Tone Ring
# Align and place the *18PTR-02: Tone Ring Cover* over the *18PTR-01: 18 Pole Tone Ring Base*
# Press the parts firmly and hold with a small weight to secure the cover to the base
{{>toc}}
h2. Tools
* Holoseat Test Stand
h2. Materials
* (optional) Instant/super glue (prefer Loctite Super Glue Ultragel Control)
* (1) 18PTR-01: 18 Pole Tone Ring Base
* (1) 18PTR-02: Tone Ring Cover
* (36) 18PTR-03: N52 3/16" x 3/16" Neodymium Cylinder Magnets
h2. Safety Issues
* Use safety glasses when working with small, high powered magnets to avoid eye injury from flying magnets
h2. Product
HS-03: 18 Pole Tone Ring
h2. Procedure
h3. 1. Place Magnets
# TBD
h3. 3. Verify Magnet Placement
# Set up the Holoseat Test Stand
## Ensure the calibrated sensor is attached to the sensor controller
## Ensure the power and USB connections are all configured according to the test stand operating instructions
## Place the new tone ring onto the tone ring adapter
# Run test
## Clear the sensor stats
## Run the stepper motor 1 revolution, in a CW direction, at 30 RPM
## Get the sensor stats and verify the number of reported poles is 18
# Remove the tone ring from the tone ring adapter
h3. 4. Complete the Tone Ring
# Align and place the *18PTR-02: Tone Ring Cover* over the *18PTR-01: 18 Pole Tone Ring Base*
# Press the parts firmly and hold with a small weight to secure the cover to the base