Safety Procedures v1 0
Version 8 (Jeremy Wright, 09/23/2012 10:44 pm)
1 | 1 | Jeremy Wright | h1. Safety Procedures v1.0 |
---|---|---|---|
2 | 1 | Jeremy Wright | |
3 | 3 | Jeremy Wright | {{toc}} |
4 | 3 | Jeremy Wright | |
5 | 3 | Jeremy Wright | h2. Introduction |
6 | 3 | Jeremy Wright | |
7 | 5 | Jeremy Wright | This document includes safety procedures that are designed to ensure the safe operation of the Shepard Test Stand. Each safety procedure item is labeled with a prefix of "STSSP", which stands for "Shepard Test Stand Safety Procedure". This prefix is followed by the number of the main section (i.e. 1.x), which is then followed by the number of the specific item. This is done so that the procedures are easy to reference for training purposes, or to point out a specific safety violation. |
8 | 5 | Jeremy Wright | |
9 | 3 | Jeremy Wright | h2. Safety Procedures |
10 | 1 | Jeremy Wright | |
11 | 6 | Jeremy Wright | * STSSP 1 - In accordance with the "NAR Motor Testing Manual":http://www.google.com/url?q=http%3A%2F%2Fwww.nar.org%2FSandT%2Fdocs%2FST-MotorTestingManual.pdf&sa=D&sntz=1&usg=AFQjCNGChzshgcfbwEm1PXViLOW7vVft5g : |
12 | 6 | Jeremy Wright | ** STSSP 1.1 - Follow NAR Safety Code where appropriate (see next section for details). |
13 | 6 | Jeremy Wright | ** STSSP 1.2 - Handle all motors and igniters per manufacturer’s instructions, including operating procedures and safe storage with particular attention to temperature and humidity. |
14 | 6 | Jeremy Wright | ** STSSP 1.3 - Should a motor under test fail catastrophically, do not approach the test stand until it is safe to do so (any debris has landed, the motor is done firing, etc). |
15 | 6 | Jeremy Wright | ** STSSP 1.4 - Should the test stand be damaged during testing, do not use the test stand for further testing until it has been repaired. |
16 | 1 | Jeremy Wright | |
17 | 7 | Jeremy Wright | * STSSP 2 - In accordance with the "NAR Model Rocket Safety Code":http://www.google.com/url?q=http%3A%2F%2Fwww.nar.org%2FNARmrsc.html&sa=D&sntz=1&usg=AFQjCNFkY3NeRakCivqyUzsVvszCllJzWg : |
18 | 7 | Jeremy Wright | ** STSSP 2.1 - Use only certified and unmodified commercial rocket motors (such as those manufactured by "Estes Rockets":http://www.google.com/url?q=http%3A%2F%2Fwww.estesrockets.com%2F&sa=D&sntz=1&usg=AFQjCNEN5a-gUdSYj_8-318YX-ZVpZRm1A ). |
19 | 7 | Jeremy Wright | ** STSSP 2.2 - Use only unmodified commercial Launch Controllers (such as the "Electron Beam Launch Controller":http://www.google.com/url?q=http%3A%2F%2Fwww.estesrockets.com%2Frockets%2Faccessories%2Flaunch-systems%2F302220-electron-beamr-launch-controller&sa=D&sntz=1&usg=AFQjCNGVESTmvPU2X9Za8q9vk93EGQfTAA ) per manufacturer’s instructions to ignite the motor under test. |
20 | 7 | Jeremy Wright | ** STSSP 2.3 - In the event of a misfire, remove the safety pin from the the Launch Controller and wait 60 seconds from the final test attempt before approaching the test stand. |
21 | 7 | Jeremy Wright | ** STSSP 2.4 - Ensure all participants and observers stay out of the Safety Radius and Exclusion Cones (including while setting up a test) as shown on the diagram below whenever the igniter is connected to the Launch Controller. See Figure 2.4. |
22 | 7 | Jeremy Wright | ** STSSP 2.5 - Ensure all participants and observers are aware of any tests about to begin. |
23 | 7 | Jeremy Wright | ** STSSP 2.6 - Always use a countdown before igniting a motor during a test. |
24 | 7 | Jeremy Wright | ** STSSP 2.7 - Only test A-E sized motors, and use the appropriate adaptors for A-D motors (see "Operating Manual":https://opendesignengine.net/projects/shepard-ts/wiki/Operating_Manual_v1_0 for more details). |
25 | 5 | Jeremy Wright | |
26 | 5 | Jeremy Wright | * STSSP 3 - Fire Prevention and Management |
27 | 1 | Jeremy Wright | |
28 | 7 | Jeremy Wright | h2. Figures |
29 | 7 | Jeremy Wright | |
30 | 8 | Jeremy Wright | *Figure 2.4* |
31 | 7 | Jeremy Wright | !Shepard_Safety_Zones_Diagram.png! |
32 | 5 | Jeremy Wright | |
33 | 5 | Jeremy Wright | h2. Glossary |
34 | 5 | Jeremy Wright | |
35 | 5 | Jeremy Wright | NAR - National Association of Rocketry |
36 | 5 | Jeremy Wright | STSSP - Shepard Test Stand Safety Procedure |