h1. Errata v1.0
2 1 Jeremy Wright
3 1 Jeremy Wright
There are a three main problems with the current design that will need to be addressed in future iterations (v1.1+).
4 1 Jeremy Wright
5 1 Jeremy Wright
# The drawer guide that is being used as a linear guide is not properly shielded from motor exhaust particulates, and thus the guide's bearings tend to foul after less than 30 test firings.
6 1 Jeremy Wright
# The data acquisition system is not capable of sample rates in excess of 15 samples per second. This is due to the fact that the thermocouple amplifier requires 70 to 100 milliseconds to do a temperature conversion (A to D).
7 1 Jeremy Wright
# The Force Sensing Resistor (FSR) used will not measure forces in excess of 10.0 Newtons. Some of the motors that this stand tests can exert a trust of 25 to 30 Newtons, so this is unacceptable.